GREEN CHOICE
Technical guides to the Siemens products in our catalogue
Each range has a main guide covering series, order number roots and services, plus detailed guides on the individual series.
How to find your way around the catalogue
Siemens updates
End of life, successor products and technical notes, explained for those whose plant is still running.
Browse by range
Choose the range used in your plant: the number shows how many guides are available.
Automation and CNC
Controllers, CNC and power suppliesSIMATIC
PLCs, distributed I/O, HMI panelsSINUMERIK
CNC numerical controlsSITOP
Power suppliesDrives
Inverters, converters and controllersSINAMICS
Converters and drivesSIMODRIVE
Machine tool drivesSIMOVERT MASTERDRIVE
DrivesMotors, motion control and starting
Motors, motion control, starting and protectionSIMOTION
Motion control systemsSIRIUS
Contactors, motor protection, soft startersOther Siemens families
Industrial communication, industrial PCs, process control and versions for harsh environments.
Other Siemens products
Smaller families in our catalogue: versions for harsh environments, drive control, photovoltaic inverters, instrumentation and legacy systemsSIMATIC NET and SCALANCE
Communication processors and industrial network switchesSIPLUS
Versions of SIMATIC, SITOP and SINAMICS for harsh environmentsSIMATIC C7
Compact controllers with operator panelSiemens manuals and documentation
Official manuals, FAQs, data sheets and certificates, always up to date on the Siemens portal.
- Details
Siemens SINUMERIK HMI: operator panels, machine control panels, PCU and TCU
On a machine tool with a SINUMERIK CNC, the operator works every day with the operator interface: the panel with the screen, the CNC keyboard, the machine control panel and often a handheld unit. These components are the most exposed to wear, impacts and dirt, and when they fail the machine can no longer be operated even if the CNC and drives work.
The E-Repair catalogue covers about 450 part numbers for SINUMERIK HMI components.
⚙️ Operator interface components
- Operator panel fronts (OP): OP 010, OP 012, OP 015, OP 019, OP 030, OP 031, OP 032 and OP 032S, with displays of different sizes (for example 15" TFT on the OP 015) and membrane or touch keys.
- Complete CNC keyboards, separate or integrated in the front.
- Machine control panels: 19" Machine Control Panel (MCP) for milling machines and lathes and MPP 310 and MPP 483 panels connected via MPI or PROFIBUS DP.
- Handheld units such as HT 6 and HT 8 and their connection modules.
- PCU 20, PCU 50 and PCU 70: the industrial PCs that run the HMI software behind the panel.
- TCU (Thin Client Unit), used with more recent systems to connect panels to the CNC.
- Videolink, to carry the video signal to panels located far from the CNC.
🔍 Roots in the E-Repair catalogue
| Root | Main content | Part numbers |
| 6FC5203 | OP fronts, keyboards, Machine Control Panels | 174 |
| 6FC5303 | MPP panels, OP 015 and OP 019 fronts, handheld unit modules | 132 |
| 6FC5200 | Operator panels, also in packages for Transline lines | 64 |
| 6FC5210 | PCU 20, PCU 50, PCU 70 | 53 |
| 6FC5247 | Videolink, fronts and components for 840D | 81 |
| 6FC5312 | TCU 20 and TCU 30 | 15 |
👉 6FC5203-0AF03-0AA0 – OP 015 front, 15" display
👉 6FC5203-0AD10-0AA0 – 19" Machine Control Panel
👉 6FC5303-1AF00-0AA0 – MPP 483 panel
👉 Search the catalogue: 6FC5203 · 6FC5303 · 6FC5210
⚠️ Typical faults
- display with worn-out backlight or unstable image
- worn or unresponsive membrane keys
- worn push buttons, selectors and potentiometers on the machine control panel
- PCU disks at end of life, with loss of the HMI software
- faulty power supplies and video or bus connections
Before sending a PCU it is essential to save an image of its disk: it contains the HMI software and the machine customisations.
🛠️ E-Repair services for SINUMERIK HMI
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
💾 Support in saving and restoring disk images, parameters and firmware.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can an OP front be repaired without changing the PCU?
Yes: front, keyboard, machine control panel and PCU are separate components and are repaired individually. The diagnosis shows which component is faulty.
✔️ Can a PCU be replaced with a more recent model?
Not always: the HMI software version and compatibility with the CNC must be checked. Repairing the original avoids reinstalling and reconfiguring.
✔️ What is needed before shipping?
The full part number from the rating plate, a description of the fault and, for PCUs, a backup image of the disk.
📚 Further reading
👉 SINUMERIK range, including 840D and 840D sl · 👉 6FC5 roots · 👉 SINUMERIK 840C, 850 and 880
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SINAMICS V20, V90 and V50
The SINAMICS V series brings together Siemens drives designed for standard applications, with simple installation and commissioning: the V20 inverter for pumps, fans and conveyors, the V90 servo drive for positioning axes and the V50 cabinet inverters for higher power ratings.
The E-Repair catalogue covers about 95 part numbers from the V series.
⚙️ The three series
| Series | Typical use | In the catalogue |
| V20 | Basic inverter for pumps, fans, conveyors and simple machines, with single-phase or three-phase supply | about 40 inverters (root 6SL3210), plus parameter loaders and spare fans |
| V90 | Servo drive for SIMOTICS S-1FL6 motors, with pulse train or PROFINET control | about 18 drives (root 6SL3210), plus filters and cables (6SL3203, 6SL3260, 6FX3002) |
| V50 | High-power cabinet inverter | about 28 part numbers including spare boards, switches and tools (6SL3351, 6SL3700, 6SL3056) |
👉 6SL3210-5BB11-2AV0 – SINAMICS V20
👉 6SL3210-5FB10-1UF0 – SINAMICS V90
👉 6SL3203-0BB21-8VA1 – filter for V90
👉 Search the catalogue: 6SL3210-5B · 6SL3210-5F · 6SL3260
⚠️ Typical faults
- power stage damaged by overloads or short circuits
- worn fans, with overtemperature
- on V90 units, communication problems with the motor encoder or damaged cables
- faulty control boards and interfaces in V50 cabinets
🛠️ E-Repair services for SINAMICS V20, V90 and V50
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
💾 Support in saving and restoring parameters.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can a V20 or a V90 be repaired?
Yes, in many cases. E-Repair carries out a diagnosis and assesses a component-level repair.
✔️ Does the V90 work with any servomotor?
No: the V90 is designed for SIMOTICS S-1FL6 motors. For a replacement, motor, encoder and cables must be checked.
✔️ What is needed for the diagnosis?
The full part number, the fault message and, if possible, a parameter backup.
📚 Further reading
👉 SINAMICS range · 👉 SINAMICS S210 · 👉 G110 and distributed inverters · 👉 SIMOTICS range
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SINAMICS G110 and distributed inverters G110D, G110M and G120D
The SINAMICS G110 is Siemens' basic inverter for small motors with single-phase supply, widely used on conveyors, fans, pumps and simple machines. Alongside the cabinet models, Siemens developed distributed inverters with a high degree of protection, for mounting directly on the machine or motor: G110D, G110M and G120D.
The E-Repair catalogue covers 112 G110 part numbers and about 25 part numbers of distributed inverters and related control units.
⚙️ SINAMICS G110 (root 6SL3211)
- single-phase 200 – 240 V supply
- versions with analogue input or USS serial interface
- versions with or without integrated interference suppression filter
- basic operator panel and PC connection kit (root 6SL3255)
Each part number identifies power, interface type and presence of the filter: the full part number from the rating plate is essential for a replacement.
⚙️ Distributed inverters
| Series | Root | Features |
| G120D | 6SL3500, 6SL3525 | PM250D Power Module with energy recovery and CU240D Control Unit, high degree of protection |
| G110D | 6SL3511 | Compact inverter with maintenance switch and integrated filter |
| G110M | 6SL3517, 6SL3566 | Motor-mounted inverter, with PM240M IP65 Power Module |
| Control Units | 6SL3544 | CU240D and CU240M in PROFIBUS and PROFINET versions, also fail-safe |
The catalogue also includes some frequency converters integrated in ET 200S and ET 200pro distributed I/O.
👉 6SL3211-0AB11-2BA0 – SINAMICS G110
👉 6SL3500-0SF01-0AA0 – SINAMICS G120D
👉 6SL3544-0FA20-1FA0 – Control Unit for distributed inverters
👉 Search the catalogue: 6SL3211 · 6SL3500 · 6SL3544
⚠️ Typical faults
- power stage damaged by overloads or short circuits on the motor
- aged capacitors, with overvoltage or undervoltage alarms
- deteriorated seals and connectors on distributed inverters, with ingress of liquids
- communication interfaces no longer working
🛠️ E-Repair services for SINAMICS G110 and distributed inverters
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
💾 Support in saving and restoring parameters.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can a G110 be replaced with a more recent inverter?
Yes, for example with a V20 or a G120C, but dimensions, connections and parameters change. If the machine is standardised on the G110, repairing the original is often simpler.
✔️ Can distributed inverters be repaired?
Yes, in many cases. The integrity of seals and connectors must also be checked to maintain the degree of protection.
✔️ What is needed for the diagnosis?
The full part number, the fault message and the data of the connected motor.
📚 Further reading
👉 SINAMICS range · 👉 SINAMICS G120, G120C, G120X · 👉 G120 power modules and control units · 👉 SINAMICS V20, V90 and V50
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SINAMICS S120: Sensor Module, Terminal Module, DRIVE-CLiQ and memory card
Around the Control Unit, Line Module and Motor Module, a SINAMICS S120 system uses many peripheral components: encoder modules, input and output modules, DRIVE-CLiQ hubs and cables, communication boards and memory cards with the firmware. They are small, but if one of them fails the drive stops.
The E-Repair catalogue covers about 155 part numbers for these components.
🧩 The components
| Component | Function | Examples from the catalogue |
| Sensor Module | Convert encoder signals to DRIVE-CLiQ, in cabinet (SMC) or high degree of protection (SME) versions | SMC10, SMC20, SMC30, SMC40, SME20, SME25, SME120, SME125 |
| Terminal Module | Additional inputs and outputs, encoder emulation and safety functions | TM15, TM17 High Feature, TM31, TM41, TM54F |
| DRIVE-CLiQ hub | Distribution of the DRIVE-CLiQ network | DMC20, DME20 |
| Option boards | Communication and additional terminals for the Control Unit | CBC10 (CAN), CBE20 (PROFINET), TB30 |
| Operator panel | Commissioning and diagnostics | BOP20 |
| Memory card | Drive firmware, licences and parameters | CompactFlash card and SD card |
| DRIVE-CLiQ cables | Connection between components | various lengths and degrees of protection |
🔍 Roots in the E-Repair catalogue
| Root | Content | Part numbers |
| 6SL3055 | Sensor Modules, Terminal Modules, hubs, option boards, BOP20 | 50 |
| 6SL3054 | CompactFlash cards and SD cards | 65 |
| 6SL3060 | DRIVE-CLiQ cables | 29 |
| 6SL3064 | Kits and accessories, also BOP20 | 11 |
| 6SL3053 | VSM10 Voltage Sensing Module | 2 |
👉 Search the catalogue: 6SL3055 · 6SL3054 · 6SL3060
⚠️ Typical faults
- Sensor Modules damaged by overvoltages or faulty encoder cables
- Terminal Modules with burnt-out input or output channels
- damaged DRIVE-CLiQ cables, with topology or communication errors
- corrupted or unreadable memory cards, with loss of firmware and parameters
The memory card holds the drive licences and parameters: keeping a copy of it is the simplest protection against long downtime.
🛠️ E-Repair services for SINAMICS S120 components
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
💾 Support in saving and restoring firmware, licences and parameters.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can a Sensor Module or Terminal Module be repaired?
Yes, in many cases. E-Repair carries out a diagnosis and assesses a component-level repair.
✔️ Does anything need reconfiguring after replacing a DRIVE-CLiQ module?
Generally the drive recognises the component; if the topology has changed it must be confirmed in the configuration. It is advisable to have a project backup.
✔️ Can the memory card be copied?
Yes, a backup copy of the memory card is strongly recommended. For licences, the manufacturer's rules must be respected.
📚 Further reading
👉 S120 control modules · 👉 S120 line modules · 👉 S120 motor modules · 👉 S120 Cabinet Modules
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SINAMICS S120 Cabinet Modules: multi-motor drives in cabinets
SINAMICS S120 Cabinet Modules are the cabinet version of the S120 system, designed for high-power multi-motor plants: several motors connected to a common DC bus, fed by one or more line modules. They are found on continuous paper and film machines, rolling mills, process lines, cranes and test benches.
The E-Repair catalogue covers 128 S120 Cabinet Modules part numbers.
⚙️ How a cabinet S120 system is built
- Line Module: feeds the common DC bus from the mains. It comes in three variants: Basic Line Module, without energy recovery; Smart Line Module, with energy recovery to the mains; Active Line Module, with controlled recovery and almost sinusoidal line current.
- Motor Module: one cabinet for each motor or group of motors, fed by the common bus.
- Control unit of the S120 platform and auxiliary modules.
🔍 Roots in the E-Repair catalogue
| Root | Content | Part numbers |
| 6SL3720 | Cabinet Motor Modules | 59 |
| 6SL3730 | Cabinet Line Modules: Basic (24), Smart (21), Active (24) | 69 |
👉 Search the catalogue: 6SL3720 · 6SL3730
⚠️ Typical faults
- power modules damaged by overloads or motor faults
- Line Module faults, which stop all motors connected to the bus
- worn fans, capacitors and internal power supplies
- faulty control boards and DRIVE-CLiQ interfaces
Many cabinet interventions are solved by replacing individual internal components, such as power blocks, interface boards or fans: see the guide to SINAMICS spare parts for chassis units.
🛠️ E-Repair services for SINAMICS S120 Cabinet Modules
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
💾 Support in saving and restoring parameters and firmware.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ If the Line Module fails, does the whole plant stop?
Yes, in configurations with a single Line Module all Motor Modules connected to the bus stop. A ready spare or an advance replacement service drastically reduces downtime.
✔️ What is the difference between Basic, Smart and Active Line Modules?
The Basic feeds the bus without returning energy; the Smart can return energy to the mains; the Active returns it in a controlled way, with less mains interference.
✔️ What is needed for the diagnosis?
The full part number of the cabinet or module, the fault messages and, if possible, a backup of the project and parameters.
📚 Further reading
👉 SINAMICS range · 👉 S120 line modules · 👉 S120 motor modules · 👉 S120 control modules
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
ES
DE
FR
IT 