GREEN CHOICE
Technical guides to the Siemens products in our catalogue
Each range has a main guide covering series, order number roots and services, plus detailed guides on the individual series.
How to find your way around the catalogue
Siemens updates
End of life, successor products and technical notes, explained for those whose plant is still running.
Browse by range
Choose the range used in your plant: the number shows how many guides are available.
Automation and CNC
Controllers, CNC and power suppliesSIMATIC
PLCs, distributed I/O, HMI panelsSINUMERIK
CNC numerical controlsSITOP
Power suppliesDrives
Inverters, converters and controllersSINAMICS
Converters and drivesSIMODRIVE
Machine tool drivesSIMOVERT MASTERDRIVE
DrivesMotors, motion control and starting
Motors, motion control, starting and protectionSIMOTION
Motion control systemsSIRIUS
Contactors, motor protection, soft startersOther Siemens families
Industrial communication, industrial PCs, process control and versions for harsh environments.
Other Siemens products
Smaller families in our catalogue: versions for harsh environments, drive control, photovoltaic inverters, instrumentation and legacy systemsSIMATIC NET and SCALANCE
Communication processors and industrial network switchesSIPLUS
Versions of SIMATIC, SITOP and SINAMICS for harsh environmentsSIMATIC C7
Compact controllers with operator panelSiemens manuals and documentation
Official manuals, FAQs, data sheets and certificates, always up to date on the Siemens portal.
- Details
Siemens SIMATIC S5: I/O modules, intelligent modules and communication processors
In a SIMATIC S5 PLC the CPU is only part of the system: inputs, outputs, positioning modules, expansion interfaces and communication processors are just as critical. A single faulty module can stop an entire machine.
This guide gathers the S5 modules in the E-Repair catalogue, grouped by function, with the part number roots to identify them.
🔌 Input and output modules
| Root | Function | Part numbers in the catalogue |
| 6ES542 – 6ES543 | Digital inputs (modules 420, 421, 430 – 436) | 46 |
| 6ES544 – 6ES545 | Digital outputs (modules 440, 441, 451) | 35 |
| 6ES546 – 6ES547 | Analogue modules | 13 |
| 6ES548 – 6ES549 | Mixed modules, accessories and terminal blocks | 24 |
👉 6ES5430-2BA11 – 430 digital inputs
🧠 Intelligent modules and interfaces
- IP modules (roots 6ES524 – 6ES526): autonomous processing for counting, positioning and closed-loop control, such as IP 240, IP 246, IP 252 and IP 263 – 266.
- IM interfaces (roots 6ES530 – 6ES532): connection of expansion racks to the central rack, such as IM 300 – 308 and IM 312 – 324.
- WF modules (root 6FM1, more than 90 part numbers): modules for positioning and axis control, such as WF 470, WF 620 – 635 and WF 705 – 726.
A faulty IM interface module can make an entire I/O rack "disappear": it is one of the first components to check when the CPU reports missing modules.
🔗 Communication processors
- CP 516 – 526 (roots 6ES551 – 6ES552): serial communication, connection of printers and peripherals.
- CP 530 – 552 (roots 6ES553 – 6ES555): communication and networks of the S5 system.
- CP 581 (root 6ES558, 36 part numbers): processor with integrated PC functionality.
- SINEC network CPs (root 6GK15), such as CP 541 and CP 560 – 571.
👉 Search the catalogue: 6ES543 · 6ES545 · 6ES552 · 6FM17
⚠️ Typical faults
- input or output channels burnt out by overvoltages or short circuits in the field
- IM interface modules with communication errors between racks
- communication processors losing the connection with peripherals or networks
- oxidised backplane bus contacts and front connectors
- damaged connecting cables (the catalogue includes more than 350 S5 cables, connectors and terminal blocks, roots 6ES57)
🛠️ E-Repair services for S5 modules
As Approved Partner Siemens – Industry Services, E-Repair works on SIMATIC S5 modules:
🔧 Component-level repair in E-Repair's certified in-house laboratory, where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished module, if available in stock and after a compatibility check.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can a single S5 I/O module be repaired?
Yes, in most cases. E-Repair carries out a diagnosis and assesses a component-level repair.
✔️ Do IP and WF modules need reconfiguring after repair?
Often yes: intelligent modules may hold parameters and settings. Before shipping it is advisable to note down or save the configuration.
✔️ What is needed to identify the module?
The full part number from the rating plate, the version if indicated and the type of rack or CPU it is mounted in.
📚 Further reading
👉 SIMATIC S5 · S5 CPUs, memory modules and power supplies · S5 HMI Legacy
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SIMATIC S5: CPUs, memory modules and power supplies
SIMATIC S5 PLCs are the generation of Siemens controllers that preceded S7. They have been discontinued for years, but still control many machines and lines, often with programs that were never migrated. When an S5 CPU or power supply fails, the goal is to get back up and running quickly with the original hardware.
In the E-Repair catalogue the S5 range counts about 1,000 part numbers. This guide covers the "heart" of the PLC: CPUs, memory modules and power supplies.
⚙️ The S5 families
- Compact S5-90U, S5-95U and S5-100U series: controllers for machines of low and medium complexity. In the catalogue: S5-95U CPUs (root 6ES509) and CPU 100, 102 and 103 for S5-100U (root 6ES510).
- S5-115U: the most widespread modular series, with CPU 941 – 945 (root 6ES594).
- S5-135U and S5-155U: systems for large and multiprocessor plants, with CPUs such as the 948 for S5-155U and PS 955 power supplies.
🧠 Memory modules
In S5 PLCs the program is often stored on removable memory modules, EPROM, EEPROM or flash (for example the 375 modules, root 6ES537, with 39 part numbers in the catalogue).
A faulty or erased memory module stops the machine even with a perfectly working CPU: keeping a copy of the program and a spare module is the simplest protection.
🔌 Power supplies
S5 rack power supplies, such as the PS 951 for S5-115U and the PS 955 for S5-135U/155U (root 6ES595, more than 50 part numbers in the catalogue), feed the CPU and modules and often house the backup battery. After decades of service they are among the components most prone to failure, mainly due to capacitor ageing.
🔍 Examples from the catalogue
👉 6ES5944-7UA11 – CPU 944 for S5-115U
👉 6ES5948-3UA11 – CPU 948 for S5-155U
👉 6ES5375-0LA11 – 375 EEPROM memory module
👉 6ES5955-3LC13 – 24 V DC power supply
👉 Search the catalogue: 6ES594 · 6ES595 · 6ES537
⚠️ Typical faults
- exhausted backup battery, with loss of the program in RAM
- power supplies with degraded capacitors, shutdowns or unstable voltages
- unreadable or erased memory modules
- CPU that does not go into RUN or stops intermittently
- oxidised contacts and connectors after many years in industrial environments
🧩 Other S5 components in the catalogue
- battery modules, for example nickel-cadmium for CPU 900, and housings (roots 6ES5980 and 6ES5981, about 30 part numbers)
- interface modules, for example V.24/RS232 for CPU 945, and SPM modules (roots 6ES5752 and 6ES5753, about 28 part numbers)
- S5-210 microcomputer systems (root 6ES5921)
- CPUs for S5-010 (root 6ES5900) and PG 605U handheld programmers (root 6ES5605)
- module holders and accessories (roots 6ES5731 and 6ES5741)
- terminal blocks, adapters and mounting accessories (roots 6ES5700, 6ES5703, 6ES5722)
🛠️ E-Repair services for SIMATIC S5
As Approved Partner Siemens – Industry Services, E-Repair supports the continuity of plants running S5 PLCs:
🔧 Component-level repair of CPUs, power supplies and modules in E-Repair's certified in-house laboratory, where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished product, if available in stock and after a compatibility check.
💾 Support in checking and copying the contents of memory modules.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can an S5 CPU still be repaired?
Yes, in most cases. E-Repair carries out a diagnosis and assesses a component-level repair; the proposal depends on the fault and on the condition of the unit.
✔️ Do I lose the program if I change the CPU?
It depends on where it is stored. If the program is on a removable memory module it can be reused; if it is only in RAM, a backup copy is needed.
✔️ Is it worth migrating to S7?
Migration requires rewriting the program and new machine checks. It is often better to keep the S5 running and plan the migration around production schedules.
📚 Further reading
👉 SIMATIC S5 · S5 I/O modules and communication processors · S5 HMI Legacy
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SIMATIC C7: compact controllers with integrated operator panel
SIMATIC C7 units are compact devices that combine a SIMATIC S7-300 PLC, an operator panel and inputs and outputs in a single housing. They were widely used on series-built machines, where they saved space and wiring.
The E-Repair catalogue covers about 95 C7 part numbers. The series is discontinued and has no direct successor: for many machines, repair is the only alternative to modifying the cabinet.
⚙️ The models
| Models | Root |
| C7-613 | 6ES7613 |
| C7-621, C7-623, C7-624, C7-626 | 6ES7621 – 6ES7626 |
| C7-633, C7-634, C7-635 | 6ES7633 – 6ES7635 |
| C7-636 (also in touch version) | 6ES7636 |
The versions differ in integrated CPU, panel type (keys or touch), display size and number of inputs and outputs. For example, in the catalogue the C7-636 Touch integrates an S7-300 315-2 DP CPU and a TP27 panel.
The catalogue also includes accessories such as batteries, IM 621 interfaces, additional I/O modules and pre-wired connectors.
👉 6ES7633-1AA00-8AA0 – SIMATIC C7-633/634
👉 6ES7626-0AA00-0AE3 – C7-626, display with front panel
👉 Search the catalogue: 6ES7626 · 6ES7633 · 6ES7635
⚠️ Typical faults
- display with worn-out backlight
- damaged membrane keyboard or touch screen
- exhausted battery, with loss of program or data
- damaged integrated input or output channels
- faults in the integrated CPU or power supply
Since PLC and panel are in the same device, a fault in the display alone can stop the whole machine: a targeted repair makes it possible to restart without re-engineering the cabinet.
🛠️ E-Repair services for SIMATIC C7
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
💾 Support in saving the PLC program and the panel project.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Is there a direct replacement for the C7?
No. Replacement generally requires a separate S7 PLC and panel, with changes to the cabinet, wiring and software.
✔️ Can just the display be repaired?
Often yes. The E-Repair diagnosis shows whether the fault concerns the panel, the CPU or the I/O.
✔️ What is needed before shipping?
The full part number, a description of the fault and, if possible, a copy of the PLC program and the HMI project.
📚 Further reading
👉 SIMATIC S7-300 · 👉 SIMATIC HMI · 👉 SIMATIC range
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SIMATIC ET 200B, ET 200L and ET 200X: legacy distributed I/O
Before ET 200S and ET 200SP, Siemens produced several distributed I/O families for PROFIBUS DP: ET 200B, ET 200L and ET 200X. They have long been discontinued, but many machines still use them and finding an equivalent spare part can be difficult.
The E-Repair catalogue covers about 140 part numbers from these three families.
⚙️ The three families
- ET 200B (about 40 part numbers): block-type I/O, made up of a terminal block (for example TB8) and a digital or analogue electronic module that plugs into it.
- ET 200L (about 50 part numbers): compact electronic blocks mounted on terminal blocks, with the ET 200L-SC variant expandable with additional terminal blocks and analogue modules, for example for PT100.
- ET 200X (about 50 part numbers): modules with a high degree of protection, up to IP67, for mounting directly on the machine. It includes basic modules (BM 141, BM 143, also in ECOFAST and DESINA versions), expansion modules (EM 142, EM 144) and even frequency converters (EM 148-FC).
🔍 Roots in the E-Repair catalogue
| Family | Main roots |
| ET 200B | 6ES7131-0, 6ES7132-0, 6ES7133-0, 6ES7134-0, terminal blocks 6ES7193-0 |
| ET 200L | 6ES7131-1, 6ES7132-1, 6ES7133-1, 6ES7123-1, terminal blocks 6ES7193-1 |
| ET 200X | 6ES7141-1, 6ES7142-1, 6ES7143-1, 6ES7144-1, 6ES7148-1, connectors 6ES7194-1 |
👉 6ES7132-0BH00-0XB0 – ET 200B electronic module, 16 digital outputs
👉 6ES7131-1BH00-0XB0 – ET 200L electronic block, 16 digital inputs
👉 6ES7141-1BD30-0XA0 – ET 200X module, 4 digital inputs IP67
👉 Search the catalogue: 6ES7132-0 · 6ES7131-1 · 6ES7141-1
⚠️ Typical faults
- damaged input or output channels
- PROFIBUS DP interface no longer communicating with the master
- deteriorated connectors and seals on ET 200X modules, with ingress of liquids
- electronics aged after decades of service on the machine
As these families are no longer in the Siemens catalogue, repairing the original module is often the only alternative to modifying the plant.
🛠️ E-Repair services for ET 200B, ET 200L and ET 200X
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can I replace an ET 200L module with an ET 200S?
Not directly: mechanics, wiring and bus configuration change. It is a plant modification that needs to be engineered.
✔️ Do the modules need reconfiguring after repair?
Generally the PROFIBUS address set on the module or terminal block must be checked. It is advisable to note it down before removal.
✔️ What is needed for the diagnosis?
The full part number of the module, the PROFIBUS address and a description of the fault.
📚 Further reading
👉 SIMATIC ET 200 · 👉 ET 200S
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SIMATIC ET 200SP, ET 200M and ET 200pro
This guide looks in detail at three widely used SIMATIC distributed I/O families: ET 200SP, the current compact platform; ET 200M, which brings S7-300 modules into the field via PROFIBUS or PROFINET; and ET 200pro, with a high degree of protection for mounting directly on the machine.
The E-Repair catalogue covers about 190 part numbers from these families.
⚙️ ET 200SP
| Root | Content | Part numbers |
| 6ES7155-6 | IM 155-6 PROFINET and PROFIBUS interface modules | 7 |
| 6ES7131-6, 6ES7132-6 | Digital input and output modules | 21 |
| 6ES7134-6, 6ES7135-6 | Analogue input and output modules | 21 |
| 6ES7136-6 | Fail-safe modules | 6 |
| 6ES7193-6 | BaseUnits and accessories | 20 |
⚙️ ET 200M
- IM 153-1, IM 153-2 interfaces (also for redundant configurations) and IM 153-4 PN (roots 6ES7153-1, -2, -4).
- Active bus modules for replacing modules while the plant is running, and mounting rails (roots 6ES7195-7 and 6ES7195-1).
- Signal modules from the S7-300 series.
⚙️ ET 200pro
- Connection modules and interfaces, also in the ECOFAST version (root 6ES7194-4, 37 part numbers).
- Digital and analogue electronic modules (roots 6ES7142-4 and 6ES7144-4) and special modules (root 6ES7148-4).
👉 6ES7155-6AA01-0BN0 – IM 155-6 PN ET 200SP
👉 6ES7134-6FB00-0BA1 – ET 200SP analogue module
👉 6ES7153-2AA00-0XB0 – IM 153-2 ET 200M interface
👉 6ES7194-4AA00-0AA0 – ET 200pro connection module
👉 Search the catalogue: 6ES7155-6 · 6ES7153 · 6ES7194-4
⚠️ Typical faults
- interface modules losing communication with the controller
- input or output channels damaged by overvoltages in the field
- BaseUnits and bus modules with damaged contacts
- on ET 200pro versions, deteriorated seals and connectors
🛠️ E-Repair services for ET 200SP, ET 200M and ET 200pro
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can an ET 200M module be replaced with the plant running?
Yes, if the station is mounted on active bus modules; otherwise it must be switched off. It is advisable to check this before the intervention.
✔️ Can ET 200SP modules be repaired?
Yes, in many cases, in particular interfaces and analogue modules.
✔️ What is needed for the diagnosis?
The full part number, the position in the station and the controller diagnostic message.
📚 Further reading
👉 SIMATIC ET 200 · 👉 ET 200S · 👉 ET 200B, L and X · 👉 S7-300 I/O modules
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
ES
DE
FR
IT 